How the De Novo Model Works
The MAVERICK measurements are based on a de novo model. This model was developed from first principles without empirical observation/calibration in bioprocesses with any particular media. The de novo model considers both static and dynamic parameters measured during the actual bioprocess runs. One of the static parameters is a formulary which includes the spectral characteristics of many chemical components in media. These include glucose, lactate, and other cell culture media components detectable by Raman. The dynamic parameters include adapting to changes in environmental factors such as ambient light, temperature, and turbidity, including cell based fluorescence. It also accounts for the characteristics of each unique device from an optical, electronic, and measurement error model perspective.
Real-time Analysis in Minutes
Measure critical bioprocess parameters now, not in weeks or months. No bioprocess runs to collect Raman spectra. No modeling required. There’s an easier way–with MAVERICK’s purpose-built de novo model. Get actionable process parameters in three easy steps: calibrate, autoclave, and start your bioprocess run. These videos show you how.
Process Analytical Technology (PAT) Made Easy
While in-line process analytical technology (PAT) offers many benefits, adoption has been hindered by technical challenges, integration issues, and significant implementation costs.
MAVERICK addresses all these issues, ushering in an era of accessible, continuous monitoring of multiple parameters. With MAVERICK, your team can stay at the forefront of Bioprocessing 4.0 and fully harness the advantages of real-time in-line bioprocess analysis (bioreactor monitoring) and control. Intuitive setup and user-friendly interface means there is no training barrier to overcome.
MAVERICK – Easy to Learn, Easy to Use
MAVERICK is intuitively designed for ease of use, requiring no prior experience with Raman spectroscopy or chemometric modeling. It features a user-friendly hub with a high-resolution color touchscreen, CFR 21 Part 11 compliant software, and an intuitive interface that simplifies in-line bioprocess analysis. With MAVERICK, mastering bioprocess monitoring is straightforward and efficient.
Instant Raman, Ready in Minutes
MAVERICK offers all the advantages of Raman-based process analytical technology (PAT) without the cost and complexities associated with developing “black box” empirical calibration models, required by conventional process spectroscopy-based methods. While it can take months and a dedicated team of experts to build and validate a robust empirical calibration model—MAVERICK only takes a simple two-point probe calibration to begin monitoring multiple key process parameters in most types of bioreactors. Just take it out of the box, and you’re already halfway through the setup process.
Already Have Raman Implemented & Having Trouble?
MAVERICK removes the need to maintain models and simply works across processes, scales, devices, and probes. Because it is a commercial off-the-shelf system (COTS), it allows for easy measurement method validation, unlike complex empirical models. Experience a cost-effective solution with little to no device maintenance. MAVERICK delivers a robust and scalable Process Analytical Technology (PAT) solution that helps advance your bioprocess through the pipeline to commercialization.
Multiplex Flex
Connect up to six measurement modules to a single MAVERICK hub to monitor process conditions and control feeds across multiple bioreactors independently and simultaneously in real-time. This setup saves valuable bench space and boosts efficiency.
Walk-Away Automation with MAVERICK
Control feeding pumps directly or relay the measurements to an existing automation or data acquisition system. Integration is simplified with analog and digital connectivity via Ethernet or OPC UA. Optional remote monitoring allows you to securely check on your bioreactors from anywhere, anytime, 24/7.
Data Visualization with MAVERICK and JMP Software
MAVERICK users can quickly visualize time-course data and compare different runs using the JMP statistical software package. To access this functionality, download the add-in tool from the 908 Devices customer support portal, or obtain a trial version of the JMP software directly from the JMP site.
MAVERICK Consumables & Services
Ensure your MAVERICK operates at peak efficiency with our range of consumables and services. We offer replacement immersion probes, calibration standards, Installation Qualification/Operational Qualification (IQ/OQ) support, and comprehensive service plans designed to maintain your favorite process analytical technology tool in optimal condition.
How Will You Use MAVERICK?
With MAVERICK you get in-line, real-time, and robust bioreactor monitoring of multiple key process parameters in biopharmaceutical manufacturing of monoclonal antibodies, recombinant proteins, and viral vectors utilizing CHO and HEK293 cell lines in a variety of media types.